Short-circuit & earth-fault detection
Detects both fault types on buried cables so the affected section is isolated fast.
- Phase-to-phase short circuit
- Single-phase earth fault
- Configurable current thresholds
Fault passage indicators for 6–35 kV underground networks — installed in ring main units (RMUs), compact substations and distribution boards. They flag the passage of a fault locally and report it to your control centre via a DCU, so crews find the faulted cable section in minutes instead of hours.
Where overhead detectors watch open lines, underground indicators are made for enclosed switchgear — compact, safe to install in cells, and connected to your supervision.
Detects both fault types on buried cables so the affected section is isolated fast.
Compact indicators that fit inside ring main units, package substations and distribution boards.
Instant on-site signalling plus remote status for the control room — no systematic field trips.
A data concentrator unit (DCU) gathers several indicators in a substation and relays events upstream.
Designed for dense urban distribution feeders and industrial substations where cables dominate.
Self-powered options with backup battery for long, dependable service inside switchgear.
Indicative characteristics — exact values depend on the selected Four-Faith model. Ask us for the datasheet matched to your network.
| Characteristic | Typical value |
|---|---|
| Network voltage | 6–35 kV underground cable networks |
| Faults detected | Phase short-circuit and single-phase earth fault |
| Local indication | Ultra-bright LED, mechanical flag or display (model-dependent) |
| Remote communication | Via DCU to SCADA / DMS (cellular, Ethernet or serial uplink) |
| Installation | Ring main units (RMU), compact / package substations, distribution boards |
| Reset | Automatic (timer), manual, or on voltage/current restoration |
| Power supply | Line/CT powered with backup battery (model-dependent) |
| Environment | Indoor MV switchgear, sealed for harsh conditions |
Several indicators in a substation report to a single DCU, which forwards fault events to your SCADA — giving operators real-time visibility of the underground network.
Indicators sit on the cables inside each ring main unit cell and watch for fault current.
A data concentrator unit collects the status of every indicator in the substation.
The DCU relays fault events to the control centre over cellular, Ethernet or serial links.
As part of the NEDA project (World Bank funding), more than 300 fault detectors were installed on the Ivorian distribution network — proof, at scale, of what fault detection delivers, delivered by the ENERTEC group.
Tell us your network voltage, RMU type and communication needs — we'll match the right Four-Faith references and send a quote.