SYNCH POWER · CONTROL SYSTEMS Abidjan · System online
Product · Fault detection

Underground fault detectors for buried MV cable networks.

Fault passage indicators for 6–35 kV underground networks — installed in ring main units (RMUs), compact substations and distribution boards. They flag the passage of a fault locally and report it to your control centre via a DCU, so crews find the faulted cable section in minutes instead of hours.

Key specifications

  • Voltage: 6–35 kV underground cable networks
  • Faults: short-circuit and earth fault
  • Install: RMU, compact substations, distribution boards
  • Comms: local indication + DCU → SCADA / DMS
Capabilities

Built for the underground distribution network.

Where overhead detectors watch open lines, underground indicators are made for enclosed switchgear — compact, safe to install in cells, and connected to your supervision.

Short-circuit & earth-fault detection

Detects both fault types on buried cables so the affected section is isolated fast.

  • Phase-to-phase short circuit
  • Single-phase earth fault
  • Configurable current thresholds

Made for RMUs & compact substations

Compact indicators that fit inside ring main units, package substations and distribution boards.

  • Cable-mounted or panel-mounted
  • Space-saving form factor
  • Safe MV switchgear installation

Local & remote indication

Instant on-site signalling plus remote status for the control room — no systematic field trips.

  • Ultra-bright LED / mechanical flag
  • On-cell display (model-dependent)
  • Remote event reporting

DCU → SCADA communication

A data concentrator unit (DCU) gathers several indicators in a substation and relays events upstream.

  • Aggregation of multiple detectors
  • Uplink to SCADA / DMS / OMS
  • Cellular, Ethernet or serial backhaul

Urban & industrial ready

Designed for dense urban distribution feeders and industrial substations where cables dominate.

  • Urban ring networks
  • Industrial site substations
  • Utility distribution automation

Reliable, low-maintenance

Self-powered options with backup battery for long, dependable service inside switchgear.

  • Line/CT powered + backup battery
  • Sealed for harsh conditions
  • Long maintenance intervals
Technical selection

Typical specifications.

Indicative characteristics — exact values depend on the selected Four-Faith model. Ask us for the datasheet matched to your network.

Underground fault detectors — typical characteristics
CharacteristicTypical value
Network voltage6–35 kV underground cable networks
Faults detectedPhase short-circuit and single-phase earth fault
Local indicationUltra-bright LED, mechanical flag or display (model-dependent)
Remote communicationVia DCU to SCADA / DMS (cellular, Ethernet or serial uplink)
InstallationRing main units (RMU), compact / package substations, distribution boards
ResetAutomatic (timer), manual, or on voltage/current restoration
Power supplyLine/CT powered with backup battery (model-dependent)
EnvironmentIndoor MV switchgear, sealed for harsh conditions
Integration

From the cell to the control room.

Several indicators in a substation report to a single DCU, which forwards fault events to your SCADA — giving operators real-time visibility of the underground network.

/01

Detectors in the RMU

Indicators sit on the cables inside each ring main unit cell and watch for fault current.

/02

DCU aggregation

A data concentrator unit collects the status of every indicator in the substation.

/03

Uplink to SCADA

The DCU relays fault events to the control centre over cellular, Ethernet or serial links.

RMU · DCU · SCADAUnderground
SCADA · DMS DCUCONCENTRATOR RMU 1DETECTOR RMU 2DETECTOR RMU 3DETECTOR BURIED CABLE · 6–35 kV
300+

Fault detectors deployed on the CI-ENERGIES network

As part of the NEDA project (World Bank funding), more than 300 fault detectors were installed on the Ivorian distribution network — proof, at scale, of what fault detection delivers, delivered by the ENERTEC group.

NEDA PROJECTCI-ENERGIES
WORLD BANKFunding
Get in touch

Need underground fault detectors for your cable network?

Tell us your network voltage, RMU type and communication needs — we'll match the right Four-Faith references and send a quote.