Current-sensing detection
Ammetric indicators that flag the passage of a fault current on the conductor.
- Short-circuit detection
- Earth-fault detection
- Adjusts to line voltage & frequency
Current-sensing fault passage indicators, JYZ-HW/HT series, clamped directly onto the overhead conductor. When a fault current passes, an ultra-bright 360° LED flags it — visible from a distance, day or night — so crews find the faulted feeder section in minutes. An optional communication unit brings that indication straight to your SCADA.
A simple, rugged device that turns hours of line patrol into a glance down the feeder — and, when connected, into a real-time SCADA event. Read our guide on fault passage indicators →
Ammetric indicators that flag the passage of a fault current on the conductor.
Ultra-bright light indication visible from a distance, from any angle.
Watch MV feeders and outgoing lines section by section.
Add a communication unit to report the indication remotely.
Self-powered by the line with backup battery for years of unattended service.
Clamped straight onto the conductor — no outage, no complex setup.
Indicative characteristics — exact values depend on the selected Four-Faith model (e.g. JYZ-HW, JYZ-HT). Ask us for the datasheet matched to your network.
| Characteristic | Typical value |
|---|---|
| Network voltage | 5–38 kV overhead lines |
| Detection | Current-sensing (ammetric): short-circuit and earth fault |
| Signalling | Ultra-bright 360° LED, visible from a distance |
| Reset | Automatic (timer), on voltage restoration, or manual |
| Communication | Optional, via communication unit / DCU to SCADA (model-dependent) |
| Power | Line-powered with backup battery, up to 10+ years (model-dependent) |
| Mounting | Clamped on the overhead conductor |
| Series | JYZ-HW, JYZ-HT (model-dependent) |
Detectors sit along the feeder. When a fault passes, every indicator upstream of it lights up; those downstream stay dark. The faulted section is the one between the last lit detector and the first dark one.
The ammetric indicators on the conductor detect the abnormal current.
Each detector that saw the fault lights a bright 360° LED, visible from the ground.
With a communication unit, the indication is relayed to the control centre.
As part of the NEDA project (World Bank funding), more than 300 fault detectors were installed on the Ivorian distribution network — the clearest proof of what overhead fault detection delivers at scale, delivered by the ENERTEC group.
Tell us your line voltage, quantities and whether you need remote reporting — we'll match the right JYZ references and send a quote.